Q1 · Dec 2019 · 2 marks
In spectrofluorimetric determination in solution
- (a) absorbance of analyte solution is kept near to 0.05
- (b) oxygen is eradicated from solution
- (c) pH of solution is controlled
- (d) wavelength of incident light is always above 400 nm Correct from the above is (1)A, B and D (2)B, C and D (3)A, B and C (4)A, C and D
Show answer
Answer: (c)
Report an error in ABC26IN0019
Q2 · Dec 2019 · 2 marks
The pair of light source and atomizer resulting highest sensitivity to atomic absorption spectrometric measurement is:
- (a) Hg lamp, nitric oxide flame
- (b) Hg lamp, graphite furnace
- (c) Hollow cathode lamp, graphite furnace
- (d) Hollow cathode lamp; acetylene-nitric oxide flame
Show answer
Answer: (c)
Report an error in ABC26IN0825
Q3 · Dec 2019 · 2 marks
Inspectrofluorimetric determination in solution
- (a) absorbance of analyte solution is kept near to 0.05 A, B and D
- (b) oxygen is eradicated from solution B, C and D
- (c) pH of solution is controlled A, B and C
- (d) wavelength of incident light is always above 400 nm 1 A, C and D
Show answer
Answer: (c)
Report an error in ABC26IN0826
Q4 · June 2019 · 2 marks
Incorrect statement for amperometric titration is
- (a) it is based on measurement of diffusion current.
- (b) its sensitivity is always higher than those of spectrophotometric titrations
- (c) it does not generally require an indicator
- (d) it requires inert atmosphere \left(\mathrm{N}_{2} / \mathrm{Ar}\right)
Show answer
Answer: (d)
Report an error in ABC26IN0829
Q5 · June 2018 · 2 marks
Height equivalent to theoretical plate (HETP) in gas liquid chromatography depends Significantly on which of the following?
- (a) Temperature of column A, B and C
- (b) Velocity of carrier gas C and D
- (c) Packing of column B, C and D
- (d) Column material A and C
Show answer
Answer: (a)
Report an error in ABC26IN0831
Q6 · Dec 2017 · 2 marks
To determine the bond parameters at 25°C, electron diffraction is generally unsuitable for both
- (a) \mathrm{O}_{3} and \mathrm{NO}_{2}
- (b) Sulfur and dry ice
- (c) \mathrm{NO}_{2} and sulphur
- (d) \mathrm{O}_{3} and dry ice
Show answer
Answer: (b)
Report an error in ABC26IN0832
Q7 · Dec 2017 · 2 marks
The peak area of differential thermal analysis curve is proportional to one or more of the following
- (a) mass loss
- (b) mass of the sample
- (c) heat of decomposition / phase change
Show answer
Answer: (d)
Report an error in ABC26IN0834
Q8 · June 2017 · 2 marks
Identify the correct statement(s) for phosphorimetric measurement from the following:
- (a) It is done after a time delay when fluorescence, if present becomes negligible A only
- (b) Immobilization of analyte increases phosphorescence. A and B
- (c) Phosphorescence decreases in the presence of heavy atoms A and C
- (d) Band C
Show answer
Answer: (b)
Report an error in ABC26IN0835
Q9 · June 2017 · 2 marks
Identify correct statements from the following:
- (a) Area of differential thermal analysis peak is proportional to amount of sample. A, B and C
- (b) Area of differential thermogravimetric analysis curve is proportional to mass loss. A, B and D
- (c) Phase transition cannot be studied , with differential scanning calorimetry. B, C and D
- (d) Simultaneous determination of two metal ions is possible with thermogravimetric analysis. A, C and D
Show answer
Answer: (b)
Report an error in ABC26IN0836
Q10 · Dec 2016 · 2 marks
The primary analytical method (not using a reference) is:
- (a) inductively coupled plasma emission spectrometry 3
- (c) anodic stripping voltammetry
- (d) isotopic dilution mass spectrometry
Show answer
Answer: (d)
Report an error in ABC26IN0837
Q11 · June 2016 · 2 marks
Decomposition temperature of \mathrm{CaCO}_{3} in thermogravimetric analysis will be highest in dynamic atmosphere of:
- (a) nitrogen
- (b) synthesis gas
- (c) 1: 1 mixture of \mathrm{O}_{2} and CO
- (d) water gas.
Show answer
Answer: (c)
Report an error in ABC26IN0838
Q12 · June 2015 · 2 marks
The pair of light source and atomizer resulting highest sensitivity to atomic absorption spectrometric measurement is: (1) Hg lamp, nitric oxide flame (2) Hg lamp, graphite furnace (3) Hollow cathode lamp, graphite furnace (4)Hollow cathode lamp; acetylene-nitric oxide flame
- (a) 1 and 2
- (b) 2 and 3
- (c) 1 and 3
- (d) 3 only
Show answer
Answer: (c)
Report an error in ABC26IN0018
Q13 · Dec 2015 · 2 marks
Correct statement for coulometry is
- (a) it is based on Faraday's law of electrolysis
- (b) It is a type of voltammetry
- (c) it is based on Ohm's law
- (d) it uses ion selective electrode
Show answer
Answer: (a)
Report an error in ABC26IN0839
Q14 · Dec 2015 · 2 marks
The calibration curve in spectrofluorimetric analysis becomes non-linear when
- (a) molecular weight of analyte is high
- (b) intensity of light source is high
- (c) concentration of analyte is high
- (d) molar absorptivity of analyte is high
Show answer
Answer: (a)
Report an error in ABC26IN0841
Q15 · Dec 2014 · 2 marks
The gas commonly used in generating plasma in Inductively Coupled Plasma Atomic Emission Spectroscopy (ICPAES) is:
- (a) Argon
- (b) Carbon dioxide
- (c) Nitrous oxide
- (d) hydrogen
Show answer
Answer: (a)
Report an error in ABC26IN0028
Q16 · June 2014 · 2 marks
The use of dynamic inert atmosphere in thermogravimetric analysis (TGA): (1) decreases decomposition temperature (2) decrease weight loss (3) reduces rate of decomposition (4) increases weight loss
- (a) decreases decomposition temperature
- (b) decrease weight loss
- (c) reduces rate of decomposition
- (d) increases weight loss
Show answer
Answer: (d)
Report an error in ABC26IN0030
Q17 · Dec 2014 · 2 marks
The gas commonly used in generating plasma in Inductively Coupled Plasma Atomic Emission Spectroscopy (ICPAES) is:
- (a) Argon
- (b) Carbon dioxide
- (c) Nitrous oxide
- (d) hydrogen
Show answer
Answer: (a)
Report an error in ABC26IN0844
Q18 · June 2014 · 2 marks
The use of dynamic inert atmosphere in thermogravimetric analysis (TGA):
- (a) decreases decomposition temperature
- (b) decrease weight loss
- (c) reduces rate of decomposition
- (d) increases weight loss
Show answer
Answer: (d)
Report an error in ABC26IN0846
Q19 · June 2014 · 2 marks
The correct statements for hollow cathode lamp (HCL) from the following are:
- (a) HCL is suitable for atomic absorption spectroscopy (AAS)
- (b) lines emitted from HCL are very narrow
- (c) the hardening of lamp makes it unsuitable for AAS
- (d) transition elements used in lamps have short life (1) A, B and C (2) B, C and D (3) C, D and A (4) D, A and B
Show answer
Answer: (a)
Report an error in ABC26IN0847
Q20 · 2011-2020 · 2 marks
Thermometric titration gives best results when
- (a) |\Delta H| is high
- (b) \boldsymbol{\Delta} \mathbf{G}<\mathbf{0}
- (c) Heat of mixing of titrant with titrant is high
- (d) Titrant is used as dilute solution The answer is
Show answer
Answer: (a)
Report an error in ABC26IN0824